Editor
     
  
     
CHROMABOND® XTR  
kieselguhr phase for liquid-liquid extraction
 
   
Features
 


base material coarse-grained kieselguhr (also known as diatomaceous earth, hydromatrix, celite)
large pore size, high pore volume, constantly high batch-to-batch quality
pH working range 1 – 13



application:
liquid-liquid extraction of highly viscous aqueous solutions such as physiological fluids (blood, plasma, and serum) in clinical chemistry, dyes in textiles, environmental and food analysis without use of a separation funnel
high water loadability without breakthrough of water during elution with organic solvents
also suited for removing small amounts of water from solvents which are not miscible with water
advantages:
fast, reproducible and economical
simultaneous preparation of several samples
no problems with phase separation ∙ no formation of emulsions
high recovery rates
saving of time and solvents
organic solutions need not to be dried after separation


General column parameters

Solvents applicable for elution
CHROMABOND XTR
max. volume capacity of aq. solution
waiting period before elution
elution volume
  diethyl ether
tert-butyl methyl ether
ethyl acetate
n-hexane
cyclohexane
toluene
dichloromethane (methylene chloride)
trichloromethane (chloroform)
solvent mixtures:
trichloromethane / methanol (90:10, v/v)
trichloromethane / methanol (85:15, v/v)
diethyl ether / ethanol (90:10, v/v)
diethyl ether / ethanol (80:20, v/v)
dichloromethane / 2-propanol (90:10, v/v)
dichloromethane / 2-propanol (85:15, v/v)
volume
amount
of adsorbent
 
1 ml
250 mg
0.25 ml
5 min
3 ml
 
3 ml
500 mg
0.5 ml
5 min
6 ml
 
6 ml
1 g
1 ml
5 - 10 min
8 ml
 
15 ml
3 g
3 ml
5 - 10 min 12 ml
 
30 ml
4.5 g
5 ml
5 - 10 min 16 ml
 
45 ml
8.3 g
10 ml
10 - 15 min
24 ml
 
70 ml
14.5 g
20 ml
10 - 15 min 40 ml
 
150 ml
37.5 g
50 ml
10 - 15 min 90 ml
 

 

Depending on the concentration of the analytes eluates can be analysed immediately, or the organic solvent is evaporated. The pH value of the aqueous solution can be altered on the column, which enables elution of different compounds of a sample under optimised conditions. Under certain circumstances, acidic, neutral, and basic compounds can be fractionated in this way.
  Eluents with too high alcohol contents cause an increase in volume of the aqueous phase on the CHROMABOND XTR. Here the column could be overloaded and the aqueous phase displaced from the column. In this case, a greater capacity column should be used.


Ordering information


column volume 1 ml
3 ml
6 ml
15 ml
30 ml
45 ml
70 ml
150 ml
  adsorbent weight 250 mg
500 mg
1 g
3 g
4.5 g
8.3 g
14.5 g
37.5 g
  pack of 100
50
30
30
30
30
30
10

CHROMABOND® XTR polypropylene columns
  730501
730502
730487
730489
730505
730506
730507
730509
CHROMABOND® XTR polypropylene columns · BigPacks
    730487.250
(pack of 250)

730507.100
(pack of 100)

CHROMABOND® MULTI 96 XTR
96er plates 96 x 150 mg, packs of 1 plate, for max. 96 x 0.2 ml aqueous solution
    738131.150M
       

CHROMABOND® XTR adsorbent
  50 bags of 14.5 g
(for max. 20 ml
aqueous solution each)
for 70 ml PP columns
with 100 PE filter elements

730585
  for NT20 with 50 PE filter elements
(dia. 10 mm)
730586
    500 g   730595.500
    1 kg   730595.1000



5 kg
730595.5000

Accessories for liquid-liquid extraction with CHROMABOND® XTR

variable polypropylene rack for 24 positions, incl. 24 PP stopcocks and 24 PP needles 730508
Glass columns on request
           



Syndicate   Print   
     
  
Copyright 2007 by MACHEREY-NAGEL GmbH & Co. KG   Imprint / Impressum Privacy StatementTerms Of Use