SPE method development kits

Designation
Contents of the kit
REF
Investigating the best separation mechanism for a clean-up procedure
CHROMABOND
standard development kit
10 columns each with 1 ml / 100 mg:
C18, C18 ec, C8, C6H5, NH2, DMA, OH, CN, SiOH, SA (SCX), SB (SAX)
730110
CHROMABOND
polymer development kit
10 columns each with 1 ml / 100 mg:
HR-X, HR-XC, HR-P, Easy, PS-H+, PS-OH
730290
Selecting the optimum RP phase for a clean-up procedure
CHROMABOND
RP development kit I
10 columns each with 3 ml / 500 mg:
C18, C18 ec, C8, C4 and 10 columns with 3 ml / 200 mg HR-P
730197
CHROMABOND
RP development kit II
10 columns each with 1 ml / 100 mg:
C18, C18 ec, C8, C4, HR-P
730207
CHROMAFIX
RP development kit I
10 cartridges each CHROMAFIX S:
C18, C18 ec, C8, C4, HR-P
731883

   
CHROMABOND
RP development kit III
10 columns each with 3 ml / 500 mg:
C18, C18 ec, C18 Hydra, C8 and 10 columns with 3 ml / 200 mg HR-P
730490
CHROMABOND
RP development kit IV
10 columns each with 1 ml / 100 mg:
C18, C18 ec, C18 Hydra, C8 and HR-P
730491
CHROMAFIX
RP development kit II
10 cartridges each CHROMAFIX S:
C18, C18 ec, C18 Hydra, C8 and HR-P
731886

   
CHROMABOND
RP development kit V
10 columns each with 3 ml / 500 mg:
C6H5, NO2, C6H11 ec, C4, C2
730492
CHROMABOND
RP development kit VI
10 columns each with 1 ml / 100 mg:
C6H5, NO2, C6H11 ec, C4, C2
730493
CHROMAFIX
RP development kit III
10 cartridges each CHROMAFIX S:
C6H5, NO2, C6H11 ec, C4, C2
731887
Selecting the optimum polar phase for a clean-up procedure
CHROMABOND
polar development kit I
10 columns each with 3 ml / 500 mg:
SiOH, Florisil®, NH2, CN, OH
730199
CHROMABOND
polar development kit II
10 columns each with 1 ml / 100 mg:
SiOH, Florisil®, NH2, CN, OH
730208
CHROMAFIX
polar development kit I
10 cartridges each CHROMAFIX S:
SiOH, Florisil®, NH2, CN, OH
731884
Selecting the optimum ion exchanger for a clean-up procedure
CHROMABOND ion exchange
development kit I
10 columns each with 3 ml / 500 mg:
SA (SCX), SB (SAX), PS-OH, PS-H+, DMA
730206
CHROMABOND ion exchange
development kit II
10 columns each with 1 ml / 100 mg:
SA (SCX), SB (SAX), PS-OH, PS-H+, DMA
730209
CHROMAFIX ion exchange
development kit I
10 cartridges each CHROMAFIX S:
SA (SCX), SB (SAX), PS-OH, PS-H+, DMA
731885

   
CHROMABOND ion exchange
development kit III
10 columns each with 3 ml / 500 mg:
SA (SCX), PSA, PCA (WCX), PS-H+
730494
CHROMABOND ion exchange
development kit IV
10 columns each with 1 ml / 100 mg:
SA (SCX), PSA, PCA (WCX), PS-H+
730495
CHROMAFIX ion exchange
development kit II
10 cartridges each CHROMAFIX S:
SA (SCX), PSA, PCA (WCX), PS-H+
731888
Phase selection for clean-up procedures for environmental samples
CHROMABOND kit for
environmental
sample preparation
10 columns each with 3 ml / 200 mg HR-P, 6 ml / 1000 mg C18 ec,
6 ml / 2000 mg C18 PAH, 6 ml / 500/1000 mg CN/SiOH,
3 ml / 500/500 mg SA/SiOH
730205
Columns are sealed in units of five columns each.

 Print   
     
  